Base Plate Corrosion and Premature Bearing failure in RO Pump
Loading...
Date
2018
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Turbomachinery Laboratory, Texas A&M Engineering Experiment Station
Abstract
On 19th Aug 2017, abnormal noise noticed from RO (Reverse osmosis)
Membrane Feed pump coupling area. Checked the vibration for pump &
motor and found very high vibration at Pump Drive end. The vibration level
at Pump DE Vertical recorded as 4.5 mm/sec (Allowable: 3 mm/sec Max.)
Pump was stopped to identify the reason for the high vibration and
abnormal noise. Checked the alignment and found the vertical offset at
motor end coupling is 0.8 mm higher than the pump end.
Customer has tried to perform the alignment with their own maintenance
team and found there is no shim at motor foot to do the necessary
correction.
Customer has approached OEM Service team.