Show simple item record

dc.contributor.advisorCaton, Jerald A.
dc.creatorPark, Yong Hun
dc.date.accessioned2010-01-15T00:04:57Z
dc.date.accessioned2010-01-16T00:40:33Z
dc.date.available2010-01-15T00:04:57Z
dc.date.available2010-01-16T00:40:33Z
dc.date.created2007-12
dc.date.issued2009-05-15
dc.identifier.urihttps://hdl.handle.net/1969.1/ETD-TAMU-2549
dc.description.abstractFuel cell performance was obtained as functions of the humidity at the anode and cathode sites, back pressure, flow rate, temperature, and channel depth. The fuel cell used in this work included a membrane and electrode assembly (MEA) which possessed an active area of 25, 50, and 100 cm2 with the Nafion® 117 and 115 membranes. Higher flow rates of inlet gases increase the performance of a fuel cell by increasing the removal of the water vapor, and decrease the mass transportation loss at high current density. Higher flow rates, however, result in low fuel utilization. An important factor, therefore, is to find the appropriate stoichiometric flow coefficient and starting point of stoichiometric flow rate in terms of fuel cell efficiency. Higher air supply leads to have better performance at the constant stoichiometric ratio at the anode, but not much increase after the stoichiometric ratio of 5. The effects of the environmental conditions and the channel depth for an airbreathing polymer electrolyte membrane fuel cell were investigated experimentally. Triple serpentine designs for the flow fields with two different flow depths was used. The shallow flow field deign improves dramatically the performance of the air-breathing fuel cell at low relative humidity, and slightly at high relative humidity. For proton exchange membrane fuel cells, proper water management is important to obtain maximum performance. Water management includes the humidity levels of the inlet gases as well as the understanding of the water process within the fuel cell. Two important processes associated with this understanding are (1) electro-osmotic drag of water molecules, and (2) back diffusion of the water molecules. There must be a neutral water balance over time to avoid the flooding, or drying the membranes. For these reasons, therefore, an investigation of the role of water transport in a PEM fuel cell is of particular importance. In this study, through a water balance experiment, the electro-osmotic drag coefficient was quantified and studied. For the cases where the anode was fully hydrated and the cathode suffered from the drying, when the current density was increased, the electro- osmotic drag coefficient decreased.en
dc.format.mediumelectronicen
dc.format.mimetypeapplication/pdf
dc.language.isoen_US
dc.subjectPEM Fuel Cellen
dc.subjectWater Transporten
dc.titleInvestigation of the performance and water transport of a polymer electrolyte membrane (pem) fuel cellen
dc.typeBooken
dc.typeThesisen
thesis.degree.departmentMechanical Engineeringen
thesis.degree.disciplineMechanical Engineeringen
thesis.degree.grantorTexas A&M Universityen
thesis.degree.nameDoctor of Philosophyen
thesis.degree.levelDoctoralen
dc.contributor.committeeMemberEnjeti, Prasad
dc.contributor.committeeMemberLalk, Thomas R
dc.contributor.committeeMemberLau, Sai C.
dc.type.genreElectronic Dissertationen
dc.type.materialtexten
dc.format.digitalOriginborn digitalen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record