NOTE: This item is not available outside the Texas A&M University network. Texas A&M affiliated users who are off campus can access the item through NetID and password authentication or by using TAMU VPN. Non-affiliated individuals should request a copy through their local library's interlibrary loan service.
Verification of the WRF model during a high ozone event over Houston, TX
dc.creator | Ames, Douglas Seeley | |
dc.date.accessioned | 2012-06-07T23:19:51Z | |
dc.date.available | 2012-06-07T23:19:51Z | |
dc.date.created | 2003 | |
dc.date.issued | 2003 | |
dc.identifier.uri | https://hdl.handle.net/1969.1/ETD-TAMU-2003-THESIS-A522 | |
dc.description | Due to the character of the original source materials and the nature of batch digitization, quality control issues may be present in this document. Please report any quality issues you encounter to digital@library.tamu.edu, referencing the URI of the item. | en |
dc.description | Includes bibliographical references (leaves 127-129). | en |
dc.description | Issued also on microfiche from Lange Micrographics. | en |
dc.description.abstract | High ozone values were observed in Houston, TX during August 25 - September 1, 2000. A comparison of WRF data with observations and MM5 data was conducted to determine the WRF model's performance in simulating the meteorological conditions that affected ozone. The most substantial errors in the WRF simulation were a cold bias during the observed high temperatures in the afternoon, and the timing of the sea breeze cycle. It was less accurate than the MM5 model for these aspects. The WRF model was more accurate at night, predicting the height of the boundary layer, cloud cover, the nocturnal low-level jet, and profiler winds in the lower levels. Multiple simulations of the WRF model were also run to test the sensitivity of the model to different parameters. The model was run with a different radiation scheme, different values for the diffusion schemes, different values for the levels of acoustic damping, and a different order for the time-splitting scheme. Most of the sensitivity runs only slightly altered the meteorological characteristics. The model run that changed the radiation to the Goddard scheme from the Dudhia scheme exhibited the largest changes overall. | en |
dc.format.medium | electronic | en |
dc.format.mimetype | application/pdf | |
dc.language.iso | en_US | |
dc.publisher | Texas A&M University | |
dc.rights | This thesis was part of a retrospective digitization project authorized by the Texas A&M University Libraries in 2008. Copyright remains vested with the author(s). It is the user's responsibility to secure permission from the copyright holder(s) for re-use of the work beyond the provision of Fair Use. | en |
dc.subject | atmospheric sciences. | en |
dc.subject | Major atmospheric sciences. | en |
dc.title | Verification of the WRF model during a high ozone event over Houston, TX | en |
dc.type | Thesis | en |
thesis.degree.discipline | atmospheric sciences | en |
thesis.degree.name | M.S. | en |
thesis.degree.level | Masters | en |
dc.type.genre | thesis | en |
dc.type.material | text | en |
dc.format.digitalOrigin | reformatted digital | en |
Files in this item
This item appears in the following Collection(s)
-
Digitized Theses and Dissertations (1922–2004)
Texas A&M University Theses and Dissertations (1922–2004)
Request Open Access
This item and its contents are restricted. If this is your thesis or dissertation, you can make it open-access. This will allow all visitors to view the contents of the thesis.