dc.description.abstract | An experimental investigation was conducted to determine the effect of test conditions and sample configuration on the AMTEC electrode/electrolyte characteristic measurements in a Sodium Exposure Test Cell (SETC). The effect of test conditions was determined by identifying the accurate correlation between sodium temperature and vapor pressure in the correct temperature range for the SETC. In addition, temperature distribution in the sodium source in SETC was determined. A correlation was identified that accurately predicted the relationship between the sodium vapor source temperature and the vapor pressure. A means to maintain the uniformity of the temperature across the electrode/electrolyte sample and in the sodium vapor source was determined. Two electrode/electrolyte configurations (tube and disk) were tested to determine if there was a difference in the characteristics determined from the measurements. It was demonstrated that the configuration of the sample had little effect (about 15%) on the measurements at typical AMTEC operating temperatures. Electrochemical Impedance Spectroscopy (EIS) and controlled potential current-voltage curves (iV curves) techniques were used to determine these characteristics. | en |
dc.format.medium | electronic | en |
dc.format.mimetype | application/pdf | |
dc.language.iso | en_US | |
dc.publisher | Texas A&M University | |
dc.rights | This thesis was part of a retrospective digitization project authorized by the Texas A&M University Libraries in 2008. Copyright remains vested with the author(s). It is the user's responsibility to secure permission from the copyright holder(s) for re-use of the work beyond the provision of Fair Use. | en |
dc.subject | mechanical engineering. | en |
dc.subject | Major mechanical engineering. | en |
dc.title | Effect of test conditions and sample configuration on the AMTEC electrode/electrolyte characteristics measurements in the Sodium Exposure Test Cell experiment | en |