Show simple item record

dc.creatorHoyt, Joel Rainer
dc.date.accessioned2012-06-07T22:52:42Z
dc.date.available2012-06-07T22:52:42Z
dc.date.created1998
dc.date.issued1998
dc.identifier.urihttps://hdl.handle.net/1969.1/ETD-TAMU-1998-THESIS-H69
dc.descriptionDue to the character of the original source materials and the nature of batch digitization, quality control issues may be present in this document. Please report any quality issues you encounter to digital@library.tamu.edu, referencing the URI of the item.en
dc.descriptionIncludes bibliographical references: p.54-57.en
dc.descriptionIssued also on microfiche from Lange Micrographics.en
dc.description.abstractThe Nevada Test Site was operated by the Department of Energy's Nevada Operations Office (DOE/NV), through 1992, as a test facility for nuclear weapons. This resulted in an environment with many unique hazards, including areas that when disturbed, could lead to intakes of radioactive material. DOE/NV Maintenance and Operations Contractor, Bechtel Nevada, operates the In Vivo Service Laboratory (IVSL) to monitor personnel for some of these intakes. To establish a standard of quality for such laboratories, the DOE has proposed the Department of Energy Laboratory Accreditation Program, or DOELAP. This program uses a new national standard on radiobioassay performance as its technical basis (HPS 1996). This standard, and the DOELAP handbook, encompass all aspects of the radiobioassay program including requirements for staffing, training, infrastructure, data handling, backup provisions, reporting, records management, document control, self assessment, performance evaluation, calibration, background and blank counting, calibration and quality control checks, personnel counting, and many other issues associated with program quality assurance. The objectives of this thesis were to perform a well-documented assessment of the IVSL, with respect to guidance documents bearing directly upon the DOELAP process, and then to implement corrective actions to bring the lung counting protocol into compliance. This work identified that while the IVSL maintained counting and quality practices generally consistent with the proposed guidelines (and within the scope of any current requirements), the program documentation was inadequate in most cases. A procedures manual was developed, in response to this finding, that included general programmatic sections as well as those specific to lung counting. A close-out assessment identified that, by generating these procedures from the known regulatory drivers, all pertinent requirements were included therein.en
dc.format.mediumelectronicen
dc.format.mimetypeapplication/pdf
dc.language.isoen_US
dc.publisherTexas A&M University
dc.rightsThis thesis was part of a retrospective digitization project authorized by the Texas A&M University Libraries in 2008. Copyright remains vested with the author(s). It is the user's responsibility to secure permission from the copyright holder(s) for re-use of the work beyond the provision of Fair Use.en
dc.subjecthealth physics.en
dc.subjectMajor health physics.en
dc.titlePreparation of an In Vivo radiobioassay program for accreditationen
dc.typeThesisen
thesis.degree.disciplinehealth physicsen
thesis.degree.nameM.S.en
thesis.degree.levelMastersen
dc.type.genrethesisen
dc.type.materialtexten
dc.format.digitalOriginreformatted digitalen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

This item and its contents are restricted. If this is your thesis or dissertation, you can make it open-access. This will allow all visitors to view the contents of the thesis.

Request Open Access