dc.description.abstractAn experimental investigation has been conducted to determine the critical heat flux for subcooled refrigerant-11 and refrigerant-113 flowing upward in a vertical cylindrical tube. Critical heat flux (CHF) values are determined for a range of tube diameters, tube lengths, and mass flow rates. Methods of developing predictive correlations for subcooled critical heat flux based on dimensional analysis, and the sublayer dryout model, are described and applied to the data from these experiments. When compared with the data from the current experimental investigation, along with water CHF data from a previous study, the three predictive methods are able to correlate the data with comparable accuracy. The predictive method based on the sublayer dryout model is expected to be applicable beyond the range of experimental parameters considered in the current study.en
dc.format.mediumelectronicen
dc.format.mimetypeapplication/pdf
dc.language.isoen_US
dc.publisherTexas A&M University
dc.rightsThis thesis was part of a retrospective digitization project authorized by the Texas A&M University Libraries in 2008. Copyright remains vested with the author(s). It is the user's responsibility to secure permission from the copyright holder(s) for re-use of the work beyond the provision of Fair Use.en
dc.subjectmechanical engineering.en
dc.subjectMajor mechanical engineering.en
dc.titleAn experimental investigation of critical heat flux in subcooled internal flowen
dc.typeThesisen
thesis.degree.disciplinemechanical engineeringen
thesis.degree.nameM.S.en
thesis.degree.levelMastersen
dc.type.genrethesisen
dc.type.materialtexten
dc.format.digitalOriginreformatted digitalen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

This item and its contents are restricted. If this is your thesis or dissertation, you can make it open-access. This will allow all visitors to view the contents of the thesis.

Request Open Access