NOTE: This item is not available outside the Texas A&M University network. Texas A&M affiliated users who are off campus can access the item through NetID and password authentication or by using TAMU VPN. Non-affiliated individuals should request a copy through their local library's interlibrary loan service.
Wind power application for low flow irrigation from the Edwards-Trinity aquifer of West Texas
dc.creator | Molla, Saiful Islam | |
dc.date.accessioned | 2012-06-07T22:49:49Z | |
dc.date.available | 2012-06-07T22:49:49Z | |
dc.date.created | 1997 | |
dc.date.issued | 1997 | |
dc.identifier.uri | https://hdl.handle.net/1969.1/ETD-TAMU-1997-THESIS-M65 | |
dc.description | Due to the character of the original source materials and the nature of batch digitization, quality control issues may be present in this document. Please report any quality issues you encounter to digital@library.tamu.edu, referencing the URI of the item. | en |
dc.description | Includes bibliographical references. | en |
dc.description | Issued also on microfiche from Lange Micrographics. | en |
dc.description.abstract | Attempts were made to reduce the cost of energy for irrigation in West Texas. To do this two wind turbines of 10 kW size were installed in Garden City and Stiles, Texas to pump water. The turbines were installed on 30 m towers. The pumping water head at Garden City and Stiles were 48 m and 80 m, respectively.A double Fourier series analysis of wind speed characteristics was done to better predict wind speed for the test areas and the use of a N=3 and M=7 harmonic term was suggested for this region. A relationship of flow pumped from a wind powered pumping system was developed to better predict flow rate based on available wind speed and pumping water depth data.The economic analysis of this system showed that if the local utility sold power at rate of $0.09kWh then a wind powered pumping system can be economically feasible if the cost of a 10 kW wind turbine was less than $5000 payable over 30 years at 5% interest rate. The current cost of such a system is $30,000, making it prohibitively expensive. However, such a system may become a more economical alternative as the cost of electricity increases and the cost of the turbines decrease. | en |
dc.format.medium | electronic | en |
dc.format.mimetype | application/pdf | |
dc.language.iso | en_US | |
dc.publisher | Texas A&M University | |
dc.rights | This thesis was part of a retrospective digitization project authorized by the Texas A&M University Libraries in 2008. Copyright remains vested with the author(s). It is the user's responsibility to secure permission from the copyright holder(s) for re-use of the work beyond the provision of Fair Use. | en |
dc.subject | agricultural engineering. | en |
dc.subject | Major agricultural engineering. | en |
dc.title | Wind power application for low flow irrigation from the Edwards-Trinity aquifer of West Texas | en |
dc.type | Thesis | en |
thesis.degree.discipline | agricultural engineering | en |
thesis.degree.name | M.S. | en |
thesis.degree.level | Masters | en |
dc.type.genre | thesis | en |
dc.type.material | text | en |
dc.format.digitalOrigin | reformatted digital | en |
Files in this item
This item appears in the following Collection(s)
-
Digitized Theses and Dissertations (1922–2004)
Texas A&M University Theses and Dissertations (1922–2004)
Request Open Access
This item and its contents are restricted. If this is your thesis or dissertation, you can make it open-access. This will allow all visitors to view the contents of the thesis.