NOTE: This item is not available outside the Texas A&M University network. Texas A&M affiliated users who are off campus can access the item through NetID and password authentication or by using TAMU VPN. Non-affiliated individuals should request a copy through their local library's interlibrary loan service.
A slotted orifice plate used as a flow measurement device
dc.creator | Macek, Michael Lee | |
dc.date.accessioned | 2012-06-07T22:32:50Z | |
dc.date.available | 2012-06-07T22:32:50Z | |
dc.date.created | 1993 | |
dc.date.issued | 1993 | |
dc.identifier.uri | https://hdl.handle.net/1969.1/ETD-TAMU-1993-THESIS-M141 | |
dc.description | Due to the character of the original source materials and the nature of batch digitization, quality control issues may be present in this document. Please report any quality issues you encounter to digital@library.tamu.edu, referencing the URI of the item. | en |
dc.description | Includes bibliographical references. | en |
dc.description.abstract | The standard orifice plate is used extensively by the natural gas industry for the metering of fuel. Because of the costs associated with errors in flow measurement inherent with the use of a standard orifice plate, any improvements upon the existing standard orifice plate design would be desirable. Consequently, a new type of orifice plate has been designed. It is termed the "slotted orifice plate". In the slotted orifice plate, the familiar round hole found in the center of standard orifice plates is replaced with a circular array of radially aligned slots. The objective of this project was to compare the performance of the slotted orifice plate to that of the standard orifice plate in order to determine the extent, if any, to which the slotted orifice plate is superior to the standard orifice plate in flow measurement. This was done by investigating pipe-wall pressure distributions and velocity profiles associated with flow through both the standard plate and the slotted plate for a variety of test cases. By using the pressure distribution and velocity profile data, coefficients of discharge were plotted against the second order radial moments of axial momentum. It was determined that the slotted orifice plate was a much more consistent flow measurement device compared to the standard orifice plate, showing less sensitivity to upstream velocity profiles and swirl | en |
dc.format.medium | electronic | en |
dc.format.mimetype | application/pdf | |
dc.language.iso | en_US | |
dc.publisher | Texas A&M University | |
dc.rights | This thesis was part of a retrospective digitization project authorized by the Texas A&M University Libraries in 2008. Copyright remains vested with the author(s). It is the user's responsibility to secure permission from the copyright holder(s) for re-use of the work beyond the provision of Fair Use. | en |
dc.subject | mechanical engineering. | en |
dc.subject | Major mechanical engineering. | en |
dc.title | A slotted orifice plate used as a flow measurement device | en |
dc.type | Thesis | en |
thesis.degree.discipline | mechanical engineering | en |
thesis.degree.name | M.S. | en |
thesis.degree.level | Masters | en |
dc.type.genre | thesis | en |
dc.type.material | text | en |
dc.format.digitalOrigin | reformatted digital | en |
Files in this item
This item appears in the following Collection(s)
-
Digitized Theses and Dissertations (1922–2004)
Texas A&M University Theses and Dissertations (1922–2004)
Request Open Access
This item and its contents are restricted. If this is your thesis or dissertation, you can make it open-access. This will allow all visitors to view the contents of the thesis.