NOTE: This item is not available outside the Texas A&M University network. Texas A&M affiliated users who are off campus can access the item through NetID and password authentication or by using TAMU VPN. Non-affiliated individuals should request a copy through their local library's interlibrary loan service.
The development and use of a trochoidal electron spectrometer for in-beam e-y coincidence measurements
dc.contributor.advisor | Sugihara, T. T. | |
dc.creator | Hughes, Michael Blalock | |
dc.date.accessioned | 2020-08-21T21:59:51Z | |
dc.date.available | 2020-08-21T21:59:51Z | |
dc.date.issued | 1977 | |
dc.identifier.uri | https://hdl.handle.net/1969.1/DISSERTATIONS-620270 | |
dc.description | Vita. | en |
dc.description.abstract | A broad-range trochoidal spectrometer, which has been used previously for prompt and delayed in-beam studies of conversion-electron spectra, has been adapted for use in the coincidence mode. After initial development of the technique in off-line experiments, an e-y coincidence study was performed in beam to obtain data for interband transitions in ¹⁵⁴Gd. Several different properties of the spectrometer, such as the electron time of flight, were measured during the initial development. The results of the in-beam experiment on ¹⁵⁴Gd are discussed with reference to the backbending phenomenon observed in some high-spin nuclear states. | en |
dc.format.extent | x, 147 leaves | en |
dc.format.medium | electronic | en |
dc.format.mimetype | application/pdf | |
dc.language.iso | eng | |
dc.rights | This thesis was part of a retrospective digitization project authorized by the Texas A&M University Libraries. Copyright remains vested with the author(s). It is the user's responsibility to secure permission from the copyright holder(s) for re-use of the work beyond the provision of Fair Use. | en |
dc.rights.uri | http://rightsstatements.org/vocab/InC/1.0/ | |
dc.subject | In-beam gamma ray spectroscopy | en |
dc.subject | Spectrometer | en |
dc.subject | Major chemistry | en |
dc.subject.classification | 1977 Dissertation H894 | |
dc.subject.lcsh | Spectrometer | en |
dc.subject.lcsh | In-beam gamma ray spectroscopy | en |
dc.title | The development and use of a trochoidal electron spectrometer for in-beam e-y coincidence measurements | en |
dc.type | Thesis | en |
thesis.degree.grantor | Texas A&M University | en |
thesis.degree.name | Doctor of Philosophy | en |
dc.type.genre | dissertations | en |
dc.type.material | text | en |
dc.format.digitalOrigin | reformatted digital | en |
dc.publisher.digital | Texas A&M University. Libraries | |
dc.identifier.oclc | 3980986 |
Files in this item
This item appears in the following Collection(s)
-
Digitized Theses and Dissertations (1922–2004)
Texas A&M University Theses and Dissertations (1922–2004)
Request Open Access
This item and its contents are restricted. If this is your thesis or dissertation, you can make it open-access. This will allow all visitors to view the contents of the thesis.