Show simple item record

dc.creatorGu, Yian
dc.date.accessioned2020-09-03T21:15:26Z
dc.date.available2020-09-03T21:15:26Z
dc.date.issued1995
dc.identifier.urihttps://hdl.handle.net/1969.1/DISSERTATIONS-1561853
dc.descriptionVita.en
dc.description.abstractThe present work is concerned with developing a discretized analytical model to investigate the effect of a backfill on the performance of a vertical U-tube ground-coupled heat pump. This work involves the development of an analytical solution and an expression for the equivalent diameter, and the experimental verification of their applications in the system model. The approximate analytical solution was developed to the transient heatconduction problem in an infinite composite medium composed of a backfill and the soil with an internal cylindrical heat source. This was intended to improve the prediction of the performance of a U-tube ground heat exchanger. The generalized orthogonal expansion technique was utilized in deriving this solution. Solutions are presented in a wide range of the Fourier number for the non-dimensional temperature as a function of the ratios of the thermal conductivities and diffusivities of the backfill and soil. Sensitivities of the results to assumptions about the sizes of the backfilling region and the far-field boundary were also examined. To verify the correctness of the solution, comparisons were made between this solution and the classical homogeneous cylindrical solution and a finite difference solution. To improve the equivalent diameter approach to the, thermal interference problem between the legs of the U-tube, a general expression for the equivalent diameter was derived under steady state. The transient analytical solution developed earlier combined with the superposition method and the conformal mapping technique were used to justify this expression. A small-scale U-tube test facility was constructed for the experimental validation of the system model of the U-tube heat exchanger using the analytical solution and the equivalent diameter expression. Two types of backfill materials: bentonite/masonry sand and bentonite/copper powder, were chosen for the tests. Finally, the parametric studies were conducted to characterize the effects of the thermal properties of the backfill, the leg spacing as well as the size of the backfill region. A backfill effectiveness was proposed and discussed. These studies provide a number of insights into the heat transfer behavior of the U-tube heat exchanger buried in a non homogeneous medium.en
dc.format.extentxviii, 165 leavesen
dc.format.mediumelectronicen
dc.format.mimetypeapplication/pdf
dc.language.isoeng
dc.rightsThis thesis was part of a retrospective digitization project authorized by the Texas A&M University Libraries. Copyright remains vested with the author(s). It is the user's responsibility to secure permission from the copyright holder(s) for re-use of the work beyond the provision of Fair Use.en
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/
dc.subjectMajor mechanical engineeringen
dc.subject.classification1995 Dissertation G8
dc.titleEffect of backfill on the performance of a vertical U-tube ground coupled heat pumpen
dc.typeThesisen
thesis.degree.grantorTexas A&M Universityen
thesis.degree.nameDoctor of Philosophyen
thesis.degree.namePh. Den
dc.type.genredissertationsen
dc.type.materialtexten
dc.format.digitalOriginreformatted digitalen
dc.publisher.digitalTexas A&M University. Libraries
dc.identifier.oclc35089601


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

This item and its contents are restricted. If this is your thesis or dissertation, you can make it open-access. This will allow all visitors to view the contents of the thesis.

Request Open Access