Show simple item record

dc.contributor.advisorBrown, K. W.
dc.contributor.advisorDonnelly, K. C.
dc.creatorAnderson, Cathy Shoemaker
dc.date.accessioned2020-08-21T22:13:30Z
dc.date.available2020-08-21T22:13:30Z
dc.date.issued1994
dc.identifier.urihttps://hdl.handle.net/1969.1/DISSERTATIONS-1549692
dc.descriptionVita.en
dc.description.abstractThis study focused on the development of a passive in situ sampling method for the detection and assessment of atmospheric contamination. Conifer needles were collected adjacent to a wood-preserving waste bioremediation facility and at a background area in a National Park. The samples were solvent extracted and bioassayed in the Salmonella microsome assay and the E . coli prophage induction assay for detection of mutagenicity. Splits of several samples were analyzed for polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDDs/PCDFs). Other samples were extracted and analyzed for pentachlorophenol. Results of the Salmonella bioassay did not indicate mutagenic activity in any of the samples collected on-site or off-site. Two samples collected on-site were weakly mutagenic in the Ej. coli assay (an assay that is more sensitive to chlorinated organics than the Salmonella bioassay). Splits of three on-site and two off-site samples were all found to contain PCDDs/PCDFs. Concentration of PCDDs/PCDFs decreased with distance southeast of the source of contamination. Concentrations of PCDDs/PCDFs in the background samples were as much as 186 times less than the concentration found on-site. The very low PCDD/PCDF concentrations detected in background samples were lower than concentrations of PCDDs/PCDFs detected in European background samples, indicating a relatively clean area for background sample collection. The chemical analyses of other samples detected pentachlorophenol in the two samples collected on-site but none in the sample collected in the background area. The results indicate that the Salmonella assay did not respond to the chlorinated contaminants and the E. coli assay did weakly respond. The maximum E^_ coli response was to a sample collected on-site. The chemical analysis was a good tool for detecting contaminants on-site and off-site, with both the PCDDS/PCDFs and the pentachlorophenol. Toxic equivalency factors were calculated for each sample analyzed for PCDD/PCDF concentrations. Sums of TEFs (TEQs) were used to compare samples with others collected on-site and at the background area. Thus the use of conifer species proved to be a good method of detecting atmospheric contaminants at a wood-preserving bioremediation facility.en
dc.format.extentxiv, 116 leavesen
dc.format.mediumelectronicen
dc.format.mimetypeapplication/pdf
dc.language.isoeng
dc.rightsThis thesis was part of a retrospective digitization project authorized by the Texas A&M University Libraries. Copyright remains vested with the author(s). It is the user's responsibility to secure permission from the copyright holder(s) for re-use of the work beyond the provision of Fair Use.en
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/
dc.subjectMajor agronomyen
dc.titleThe utilization of conifer species to detect chlorinated atmospheric contaminants at a wood-preserving waste bioremediation facilityen
dc.typeThesisen
thesis.degree.grantorTexas A&M Universityen
thesis.degree.nameDoctor of Philosophyen
thesis.degree.namePh. Den
dc.contributor.committeeMemberAutenrieth, R.
dc.contributor.committeeMemberNewton, R.
dc.type.genredissertationsen
dc.type.materialtexten
dc.format.digitalOriginreformatted digitalen
dc.publisher.digitalTexas A&M University. Libraries
dc.identifier.oclc34706586


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

This item and its contents are restricted. If this is your thesis or dissertation, you can make it open-access. This will allow all visitors to view the contents of the thesis.

Request Open Access