NOTE: Restrictions are in place to limit access to one or more of the files associated with this item. Authorized users must log in to gain access. Non-authorized users do not have access to these files.
Visit the Energy Systems Laboratory Homepage.
dc.creator | Fox, B. J. | |
dc.date.accessioned | 2010-11-29T15:28:19Z | |
dc.date.available | 2010-11-29T15:28:19Z | |
dc.date.issued | 1986-06 | |
dc.identifier.other | ESL-IE-86-06-117 | |
dc.identifier.uri | https://hdl.handle.net/1969.1/93083 | |
dc.description.abstract | The required temperature and technique for condensing common industrial solvents from the exhaust air of drying ovens is explained. The benefits of the Air Cycle for this application are discussed. The operation of the 8000 CFM Air Cycle Solvent Recovery System developed by the AiResearch Manufacturing Company of California under contract to the Department of Energy is discussed. Performance data for the recovery of solvents from an industrial drying oven is presented. The advantages of the "free spindle" arrangement as an alternate to the present gear drive are explained. The simple method for adjusting and controlling the turbine exhaust temperature for the "free spindle" arrangement is explained. The application of the Air Cycle for condensing solvent vapors from inert atmosphere ovens and from activated carbon desorbed with nitrogen is also described. Relative merits of the Air Cycle System compared with other available methods of solvent recovery are discussed. | en |
dc.language.iso | en_US | |
dc.publisher | Energy Systems Laboratory (http://esl.tamu.edu) | |
dc.subject | Solvent Recovery System | en |
dc.subject | Air Cycle System | en |
dc.subject | 'Free Spindle' Arrangement | en |
dc.title | The Air or Brayton Cycle Solvent Recovery System | en |
dc.type | Presentation | en |
This item appears in the following Collection(s)
-
IETC - Industrial Energy Technology Conference
Industrial Energy Technology Conference