dc.description.abstractIn 1989 American & Efird, Inc., decided to upgrade their heat recovery system at its Dyeing & Finishing Plant in Mt. Holly, North Carolina. They chose an electric industrial process heat pump to enhance heat recovery and to lower operating costs. This application of the industrial process heat pump was the first of its kind in the American textile industry and was the result of a three year cooperative effort between American & Efird, Inc. and Duke Power Company. This innovative application of heat pump technology has allowed American & Efird to gain additional boiler capacity, lower waste water discharge temperatures and achieve significant energy savings. Duke Power will gain an additional 572,000 KWH in annual sales, of which approximately 70 percent will occur during off-peak hours, and American & Efird will enjoy lower overall energy costs.en