The Measured Energy Impact of Infiltration Under Dynamic Conditions
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1992-05)
Energy consumption due to air infiltration is customarily assumed to equal the mass flow rate times the specific enthalpy difference between the inside and outside air. Anderlind showed theoretically that this represents ...
Disaggregating Cooling Energy Use of Commercial Buildings Into Sensible and Latent Fractions From Whole-Building Monitored Data: Methodology and Advantages
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1992-05)
In hot and humid climates, where summers are both warm and humid, the latent cooling can be a significant portion of the total cooling load (as much as 40%). Typically the monitored data only includes whole-building heating ...
Survey of Energy Use in Grocery Stores
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1992-05)
This paper presents the results of an energy use survey assembled for 93 grocery stores in south Texas. All stores were of the same chain. Several conclusions were drawn. Total electricity consumption per square foot is ...
The Measured Energy Impact of Infiltration in an Outdoor Test Cell
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1992-05)
The energy consumption calculation of house envelopes assumes that conduction heat loss is independent on air infiltration heat loss, and that energy consumption is the sum of these losses. Anderlind [1985], Liu [1987], ...
Development of the Potential Energy Savings Estimation (PESE) Toolkit
(Energy Systems Laboratory (http://esl.tamu.edu), 2010-08)
This study has developed a prototype computer tool called the Potential Energy Savings Estimation (PESE) Toolkit. Baltazar’s methodology for potential energy savings estimation from EBCx/retrofit measures has been improved ...
Daylighting Design Tools in Atria for Minimum Cooling Loads in Atrium Buildings
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1992-05)
The daylighting and sunlighting value of an atrium are considered the main reasons for including the atrium use in the built environment. However, most atria today are either overlit, which causes tremendous cooling loads, ...
Airside Economizer – Comparing Different Control Strategies and Common Misconceptions
(Energy Systems Laboratory, 2008-12)
Air-side economizer is broadly adopted in building HVAC design and operations. When the system is properly designed and the control sequence is properly implemented, air-side economizer provides significant energy savings. ...