Simulation of Dehumidification Characteristics of High Efficiency Residential Central Air-Conditioners in Hot and Humid Climates
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1988)
This study assesses the dehumidifying performance
of the high efficiency residential central air conditioners
(CAC) in hot/humid climates typified
by that of Houston and Galveston. The performance
study is based on such ...
An Evaluation of the Placement of the Placement of Radiant Barriers on their Effectiveness in Reducing Heat Transfer in Attics
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1986)
Experimental tests were conducted to
measure the influence of radiant barriers
and the effect of the radiant barrier
location on attic heat transfer. All the
tests were conducted in an attic simulator
at a steady state. ...