Search
Now showing items 161-170 of 196
Development of Temperature and Humidity-Based Indicators for Diagnosing Problems in Low Tonnage, Split System Air Conditioners
(Texas A&M University (http://www.tamu.edu)Energy Systems Laboratory (http://esl.tamu.edu), 1998)
This paper presents results of a survey of the
literature and identifies the most common degraded
conditions associated with low-tonnage air
conditioners. Other laboratory studies as well as
marketed diagnostic systems ...
Emerging, Cost-Effective Applications for Desiccant Dehumidification in the U.S.
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1998)
Gas-fired desiccant dehumidification systems are
now being specified for many supermarkets, ice
arenas and cold warehouses, with installations now
numbering in the thousands. Their cost effectiveness
is due to the economic ...
A Collaborative Support System for the Review of Building Energy Data in the LoanSTAR Monitoring and Analysis Project
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1992-05)
The LoanSTAR Monitoring and Analysis Project (MAP) collects a large volume of data pertaining to the analysis of building energy usage. Experts within the project review these data for accuracy. This review is collaborative, ...
Statistical Modeling of Daily Energy Consumption in Commercial Buildings Using Multiple Regression and Principal Component Analysis
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1992-05)
Statistical models of energy use in commercial buildings are being increasingly used not only for predicting retrofit savings but also for identifying improper operation of HVAC systems. The conventional approach involves ...
Reducing Building Energy Costs Using Optimized Operation Strategies for Constant Volume Air Handling Systems
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1994)
Building energy consumption can be substantially
reduced after implementing what we call Extended
O&M Measures. The Extended O&M Measures are a
scientific refinement of traditional O&M measures.
Specifically, they ...
Plain Talk About Condensation and Radiation Below Metal Roof Assemblies
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1992-05)
During recent decades an increasing number of users have chosen metal roofing for various commercial, industrial and institutional buildings. Because of several advantages, construction of new pre-engineered and "hybrid" ...
A Methodology to Identify Monthly Energy Use Models from Utility Bill Data for Seasonally Scheduled Buildings: Application to K-12 Schools
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1998)
The measured energy savings from retrofits
in buildings is often determined as the difference
between the energy consumption predicted by a
baseline model and the measured energy
consumption during the post retrofit ...
Outdoor Air, Heat Wheels and JCPenney: A New Approach to Retail Ventilation
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1998)
JCPenney Construction Services department is
responsible for the construction of new stores, takeover
of existing facilities to create a new store,
repairs to existing JCPenney facilities and the
expansion and modernization ...
The Texas LoanSTAR Program: Acquiring and Archiving LoanSTAR Data
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1990)
This paper discusses the acquisition and archiving of data for the
Texas LoanSTAR monitoring program, an eight year, $98
million revolving loan program for energy conservation retrofits
in Texas state, local government and ...
LoanSTAR Energy Conservation Audits: January 1989 - August 1990
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1990)
Fourteen audit reports, covering seventy buildings
and Texas' Governor's mansion, have been accepted as a
part of the Texas LoanSTAR Program. Task 1 (the first of
five) is responsible for audit reviews and assignments. ...