Search
Now showing items 1-2 of 2
Investigation and Resolution of Governing Valve Linkage Failure for Compressor Drive Steam Turbine
(Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2018)
Fatigue failure of Governing Valve Linkage Rod end bearing and wear marks on several parts was observed on a extraction steam turbine (driving a centrifugal compressor) after it was in service for more than 9 year. The top ...
Investigation and Resolution of Governing Valve Linkage Failure for Compressor Drive Steam Turbine
(Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2018)
Fatigue failure of Governing Valve Linkage Rod end bearing and wear marks on several parts was observed on a extraction steam turbine (driving a centrifugal compressor) after it was in service for more than 9 year. The top ...