Investigation of unexpected Trips in Steam Turbine
(Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2018)
A 56 MW steam turbine tripped several times over a short period of time
although the trip signal was not sent. A thorough examination of the turbine at site ruled out any problems with the trip system. The pressure data ...