Torsional Oscillation Trouble on VFD Motor Driven Recip Compressor
(Texas A&M University. Turbomachinery Laboratories, 2008)
High vibration problems including failed coupling parts on a VFD motor driven reciprocating compressor are analyzed and the root causes and solutions are discussed in this costly field issue.
Development and Implementation of VFD Active Damping to Smooth Torsional Vibrations on a Geared Train
(Texas A&M University. Turbomachinery Laboratories, 2008)
VFD Induced Coupling Failure
(Texas A&M University. Turbomachinery Laboratories, 2008)
A catastrophic failure of a high performance disc coupling connecting the speed increaser and LP compressor in a VFD controlled 18,300 HP motor/speed increaser/LP compressor/HP compressor train, led to months of reduced ...