Search
Now showing items 1-2 of 2
STABILITY CONSIDERATIONS: A SIMPLIFIED APPROACH
(Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2011)
In many cases it is necessary to judge the stability behavior
of a specific compressor. This might be the OEM checking the
feasibility of a proposed compressor layout or it might be the
user judging one of his machines ...
Large Vibrations on a Centrifugal Compressor Caused by High Windage Heating on a Flexible Coupling–Root Cause Analysis and Solutions
(Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2011)
Background: 2 parallel trains consisting of a Low Pressure (LPC) and High Pressure (HPC) compressors were supplied for an offshore reinjection application near the coast of Angola. During the commissioning on site large ...