Baseline Report for the Fort Hood Army Base: Sept. 1, 2002 - Aug. 31, 2003
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2003)
This report presents electricity, natural gas and cooling baselines for the thermal plant, buildings located in the 87000 block, III Corp building and other buildings that were determined to be part of the ESPC project at ...
Monitoring and Verification Procedures Used in the Texas LoanSTAR and Rebuild America Programs
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2001)
The monitoring and verification procedures that
have been developed for the Texas LoanSTAR
program and the ESL's Rebuild America Program
have become a foundation for a number of other state
and federal M&V programs, including ...
Experiences on the Implementation of the 'Energy Balance' Methodology as a Data Quality Control Tool: Application to the Building Energy Consumption of a Large University Campus
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2007)
As the energy costs have been increasing the more energy efficient measures have been promoted in the buildings sector, the reliability of energy consumption data has been attracting significant attention. For example, the ...
Continuous Commissioning® of an Office/Laboratory Building
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2005)
Retrofit Savings Determination for Wichita Falls Independent School District
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2001)
Development of Load Forecasting Procedures for the Texas A&M University System
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2001)
This paper reports on the effort to develop load-forecasting procedures for the Texas A&M University System
(TAMUS). Such procedures are being investigated to determine if the TAMUS can benefit from the pending
deregulation ...
Retrofit Savings for Brazos County
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2001)
This report presents the energy and dollar savings for the period May 2000 - April 2001 for 10 of the Brazos County facilities that have been retrofit. The electricity use saved was 555,170 kWh and the demand was 1062 kW, ...
Energy Savings Report For Dallas County, July 2000 – June 2001
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2001)
This report presents the energy and dollar savings for the period July 2000 - June 2001 for 12 Dallas County facilities that have been retrofit by Enershop. The savings for this period total $745,046, which represent 73.2% ...
Methodology for the Determination of Potential Energy Savings in Commercial Buildings
(Texas A&M University (http://www.tamu.edu)Energy Systems Laboratory (http://esl.tamu.edu), 2007)
This paper describes a methodology to determine potential energy savings of buildings with limited information. This methodology is based upon the simplified energy analysis procedure of heating, ventilation and air condition ...