Recommendations for 15% Above-Code Energy Efficiency Measures for Residential Buildings
(Energy Systems Laboratory, 2008-11)
This report presents detailed information about the recommendations for achieving 15% above-code energy performance for single-family residences. The analysis was performed using a simulation model of an International ...
Water/Wastewater Engineering Report (High Efficiency Pump/Motor Replacement - M2 Model)
(2006-10-30)
Pumping water or wastewater is the largest use of electricity for a municipal water supply or wastewater treatment plant. Increasing the overall efficiency of the pumping system can achieve significant energy savings. ...
Description and Comparison of the Results of the Proposed House: Habitat for Humanity at Frazier Court, Dallas, Texas, with the 2004 IECC Standard Reference House
(Energy Systems Laboratiry, 2010-09)
The Energy Systems Laboratory was requested to calculate the emissions reductions associated
with the Habitat for Humanity Housing Project at Frazier Court, Dallas Texas. This report presents the
results of the required ...
Savings Report for the Fort Hood Army Base
(2005-12)
This report presents electricity consumption and electric demand savings analysis for the Thermal Plant, buildings located in the 87000 block, III Corp building and other buildings that were determined to be part of the ...
ESL Monthly Energy Consumption Report (MECR) Production Manual
(Energy Systems Laboratory (http://esl.tamu.edu), 2005-03)
Energy Efficiency, Cost-Effectiveness, and Air Pollutant Reduction Analysis From Energy Efficiency and Renewable Energy (EE/RE) Projects in Texas Public Schools
(Energy Systems Laboratory (http://esl.tamu.edu), 2010-08)
The purpose of this report is to provide the preliminary results from an analysis of the potential energy
savings, and resultant air pollution reductions associated with the energy savings from the application of
cost-effective ...
Water/Wastewater Engineering Report (Storm Sewer/Infiltration Sanitary Sewage Separation-M1 Model)
(2006-10-30)
In some cities, the municipal sewer system collects both storm water and sanitary sewage in the same pipes. During dry weather these sewers carry all the sanitary sewage to the wastewater treatment plant for treatment. ...
Development of a Residential Code-Compliant Calculator for the Texas Climate Vision Project
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2007-12)
The United States Environmental Protection Agency (EPA) has designated four areas in Texas as having unacceptable ozone levels in excess of the National Ambient Air Quality Standard (NAAQS) limits, leading to a designation ...
Energy Efficiency/Renewable Energy Impact in the Texas Emissions Reduction Plan (TERP), Volume III - Appendix, Annual Report to the Texas Commission on Environmental Quality, January 2006 - June 2007
(2009-02-20)
The Energy Systems Laboratory, at the Texas Engineering Experiment Station of the Texas A&M University System, in fulfillment of its responsibilities under Texas Health and Safety Code Ann. § 388.003 (e), Vernon Supp. 2002, ...
Baseline Report for the Fort Hood Army Base: September 2003 to October 2004
(2007-09-21)
This report presents electricity, natural gas and cooling baselines for the Thermal Plant, III Corp building,
Darnall Hospital, Main Substation, West Substation, and North Substation.
The baselines developed for this ...