dc.descriptionCase Study
dc.description.abstractWhile we go to great efforts to properly set rotating equipment, often consideration is not made to protect the base, and foundation system from erosion or corrosion. In this case study severe erosion of the foundation took place as the pump seals failed. This allowed for the acid to soak into the foundation causing it to deteriorate. We will go through the process of restoring the foundation and protecting it from further chemical attach.