Show simple item record

dc.contributorAsia Turbomachinery & Pump Symposium (2nd : 2021)
dc.creatorBhattacharya, Mantosh
dc.date.accessioned2023-02-23T20:10:34Z
dc.date.available2023-02-23T20:10:34Z
dc.date.issued2021
dc.identifier.urihttps://hdl.handle.net/1969.1/197466
dc.descriptionCase Studies
dc.description.abstractTwo mission critical electric motor driven BFW (Boiler Feed Water) pumps installed in remote site, facedcontinuous failures of rotor-stator seizures during commissioning and start up of Sulfur recovery units -Pumps had to be refurbished many times at service center by shifting from site and complete dismantling One of the Electric Motor faced several months of outage , bent rotor due to start up attempts These activity posed critical concern over project completion schedule
dc.format.mediumElectronic
dc.format.mimetypeapplication/pdf
dc.language.isoen
dc.publisherTurbomachinery Laboratory, Texas A&M Engineering Experiment Station
dc.relation.ispartofAsia Turbomachinery & Pump Symposia. 2021 Proceedings
dc.titleCS04: Mitigation of perennial seizure of boiler feed water pumps during commissioning of refinery unit