dc.description.abstractAccidental gas releases are detected by allocating sensors in optimal places to prevent escalation of the incident. Gas release effects are typically assessed based on calculating the dispersion from releasing points. In this work, a CFD-based approach is proposed to estimate gas dispersion and then to obtain optimal gas sensors allocation. The Ansys-Fluent commercial package is used to estimate concentrations in the open air by solving the governing equations of continuity, momentum, and energy combined with the realizable κ-ε model for turbulence viscosity effects and species convection-diffusion. CFD dynamic simulations are carried out for potential gas leaks, assuming worst-case scenarios with F-stability and 2 m/s wind speed during a 4min releasing period and considering 8 wind directions. The result is a scenario-based methodology to allocate gas sensors supported on fluid dynamics models. The three x-y-z geographical coordinates for the sensor allocation are included in this analysis. To highlight the methodology, a case study considers releases from a large container surrounded by different types of geometric units including sections with high obstacles, low obstacles, and no obstacles. A non-redundant set of perfect sensors are firstly allocated to cover 100% detection for all simulations releases. The benefits of redundant detection via a MooN voting arranging scheme is also discussed. Numerical results demonstrate the capabilities of CFD simulations for this application and highlight the dispersion effects through obstacles with different sizes.en
dc.format.extent16 pagesen
dc.languageeng
dc.publisherMary Kay O'Connor Process Safety Center
dc.relation.ispartofMary K O'Connor Process Safety Symposium. Proceedings 2015.en
dc.rightsIN COPYRIGHT - EDUCATIONAL USE PERMITTEDen
dc.rights.urihttp://rightsstatements.org/vocab/InC-EDU/1.0/
dc.subjectCFDen
dc.titleA CFD-based Approach for Gas Detectors Allocationen
dc.type.genrePapersen
dc.format.digitalOriginborn digitalen
dc.publisher.digitalTexas &M University. Libraries


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record