dc.description | Case Study | en |
dc.description.abstract | During an investigation of bore damage on a flexible coupling between a motor and pump, the hubs non uniform design came into question as a potential factor. The American National Standard Flexible couplings Keyless Fits (ANSI/AGMA 9003-C17 or 9103-C17),provides a good guideline for the design, inspection and instalment of hubs having a uniform cross sections. What if the hub is not of a uniform cross section? | en |