Show simple item record

dc.contributor.otherTurbomachinary Symposium (48th : 2019)
dc.creatorCich, Stefan
dc.creatorMoore, Jeff
dc.creatorDay-Towler, Meera
dc.date.accessioned2020-08-06T19:13:35Z
dc.date.available2020-08-06T19:13:35Z
dc.date.issued[2019]
dc.identifier.urihttps://hdl.handle.net/1969.1/188569
dc.descriptionCase Studyen
dc.description.abstractDuring the testing of a 1 MWe power loop with super critical co2, it was discovered that dry ice formation across dry gas seals would be an issue. This case study looks at the negative effects of dry ice formation and how the problem can be prevented during loop transient operation, mainly during filling and steady hold conditions.en
dc.format.mediumElectronicen
dc.format.mimetypeapplication/pdf
dc.language.isoeng
dc.publisherTurbomachinery Laboratory, Texas A&M Engineering Experiment Station
dc.relation.ispartofProceedings of the 48th Turbomachinery Symposiumen
dc.titleCSP11 - Testing and Troubleshooting of Pump Dry Gas Seals Operating with sCO2en
dc.type.genreconference publicationen
dc.type.materialtexten
dc.format.digitalOriginborn digitalen
dc.publisher.digitalTexas A & M University. Libraries


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record