Show simple item record

dc.contributor.otherTurbomachinery Symposium (47th : 2018)
dc.creatorKumar, Arun
dc.creatorBrar, Navneet Singh
dc.date.accessioned2019-03-12T19:49:22Z
dc.date.available2019-03-12T19:49:22Z
dc.date.issued2018
dc.identifier.urihttps://hdl.handle.net/1969.1/175077
dc.descriptionCase Studyen
dc.description.abstractThis case study of a typical tandem arrangement dry gas seal failure during compressor start-up elaborates importance of start-up environment consideration during design for a compressor dry gas seal system. The seal failed due to oil ingress during compressor start-up. The case study presentation details out following major contents: * Chronological events leading to dry gas seal failure, relevant data * Findings/observations during subsequent maintenance * Root cause analysis and outcomes * Corrective actions & subsequent performance * Key learningen
dc.format.mediumElectronicen
dc.format.mimetypeapplication/pdf
dc.language.isoen
dc.publisherTurbomachinery Laboratory, Texas A&M Engineering Experiment Station
dc.relation.ispartofProceedings of the 47th Turbomachinery Symposiumen
dc.subject.lcshTurbomachinesen
dc.titleCompressor Dry Gas Seal Failure Due To Oil Ingressen
dc.type.genreconference publicationen
dc.type.materialTexten
dc.format.digitalOriginborn digitalen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record