dc.contributor.other | International Pump Users Symposium (34th : 2018) | |
dc.creator | Annese, Francesco | |
dc.creator | Ficele, Letizia | |
dc.creator | Lisanti, Emanuele | |
dc.date.accessioned | 2019-03-12T19:48:55Z | |
dc.date.available | 2019-03-12T19:48:55Z | |
dc.date.issued | 2018 | |
dc.identifier.uri | https://hdl.handle.net/1969.1/175009 | |
dc.description | Lecture | en |
dc.description.abstract | In this paper, a combined study between Computational Fluid Dynamics (CFD) and a model test has been carried on a Cooling Water Pumping Station as part of a new power plant. The aim of this work was to validate a water pit layout, more compact than required by ASME ANSI HI 9.8 2012 design guidelines. | en |
dc.format.medium | Electronic | en |
dc.format.mimetype | application/pdf | |
dc.language.iso | en | |
dc.publisher | Turbomachinery Laboratory, Texas A&M Engineering Experiment Station | |
dc.relation.ispartof | Proceedings of the 34th International Pump Users Symposium | en |
dc.subject.lcsh | Pumping machinery | en |
dc.title | Cooling Water Pump Station Optimization Using CFD and Physical Model Test | en |
dc.type.genre | conference publication | en |
dc.type.material | Text | en |
dc.format.digitalOrigin | born digital | en |