dc.contributor.other | International Pump Users Symposium (34th : 2018) | |
dc.creator | Patterson, Donnie | |
dc.date.accessioned | 2019-03-12T19:48:45Z | |
dc.date.available | 2019-03-12T19:48:45Z | |
dc.date.issued | 2018 | |
dc.identifier.uri | https://hdl.handle.net/1969.1/174979 | |
dc.description | Case Study | en |
dc.description.abstract | This case study demonstrates the steps taken to solve a structural resonance issue on a VFD driven vertical pump installed in the field. Topics discussed include problem validation, steps taken to solve the issue, the resulting reduction in vibration amplitude, and key takeaways. | en |
dc.format.medium | Electronic | en |
dc.format.mimetype | application/pdf | |
dc.language.iso | en | |
dc.publisher | Turbomachinery Laboratory, Texas A&M Engineering Experiment Station | |
dc.relation.ispartof | Proceedings of the 34th International Pump Users Symposium | en |
dc.subject.lcsh | Pumping machinery | en |
dc.title | Structural Natural Frequency
Tuning on a Vertical Pump | en |
dc.type.genre | conference publication | en |
dc.type.material | Text | en |
dc.format.digitalOrigin | born digital | en |