Texas A&M University LibrariesTexas A&M University LibrariesTexas A&M University Libraries
    • Help
    • Login
    OAKTrust
    View Item 
    •   OAKTrust Home
    • Colleges and Schools
    • Office of Graduate and Professional Studies
    • Electronic Theses, Dissertations, and Records of Study (2002– )
    • View Item
    •   OAKTrust Home
    • Colleges and Schools
    • Office of Graduate and Professional Studies
    • Electronic Theses, Dissertations, and Records of Study (2002– )
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Design and Verification of Shape Memory Polymer Embolization Devices for Peripheral Indications

    Thumbnail
    View/Open
    LANDSMAN-DISSERTATION-2016.pdf (2.272Mb)
    Date
    2016-08-03
    Author
    Landsman, Todd Lawrence
    Metadata
    Show full item record
    Abstract
    Polyurethane shape memory polymers (SMPs) have found a variety of uses in the medical industry in the form of self-tightening sutures, suture anchors, ligament fixation devices, vascular stents, and thrombectomy devices. New formulations of polyurethane SMP scaffolds are gaining significant interest for use in vascular embolization procedures. These scaffolds have demonstrated rapid time to occlusion, improved healing, and favorable biocompatibility, and they eliminate the need to implant multiple devices to achieve stable occlusion, significantly reducing procedure times and the total cost of treatment. Described here are various methods used to fabricate SMP scaffolds, indications for SMP scaffold embolization, advantages of using these scaffolds in embolization procedures, results seen in vivo and in vitro to verify the safety and efficacy of the SMP scaffolds, and future directions for SMP scaffolds that will propel the technology to significant use beyond vessel occlusion. The research described in this work resulted in the creation of novel embolic devices that have the potential to drastically reduce the cost of endovascular embolization procedures by reducing the number of devices required for treatment, radiation time, the need for repeat procedures, and the time to complete healing of the treated vessel. These devices also demonstrated resistance to undesired thromboembolism in vitro, while also exerting negligible radial force on the vessel endothelium to minimize the likelihood of vessel rupture or perforation. In vitro verification testing demonstrated that this device appears to be safe and effective for embolization within the peripheral vasculature. This work also represented the first verification of the echogenicity of shape memory polymer foam devices in vitro. In addition, this research solidified the designation of polyurethane shape memory polymer foam as a platform technology that can be combined with other material systems to create shape memory occlusive devices with enhanced fluid uptake and bactericidal properties.
    URI
    http://hdl.handle.net/1969.1/174257
    Subject
    embolization
    medical device
    venous insufficiency
    Shape Memory Polymer
    Collections
    • Electronic Theses, Dissertations, and Records of Study (2002– )
    Citation
    Landsman, Todd Lawrence (2016). Design and Verification of Shape Memory Polymer Embolization Devices for Peripheral Indications. Doctoral dissertation, Texas A & M University. Available electronically from http : / /hdl .handle .net /1969 .1 /174257.

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Advanced Search

    Browse

    All of OAKTrustCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsDepartmentThis CollectionBy Issue DateAuthorsTitlesSubjectsDepartment

    My Account

    LoginRegister

    Statistics

    View Usage Statistics
    Help and Documentation

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV