Compressor rotor failure due to fouling at Qatargas condensate refinery
Abstract
•Process Overview
•Hydrogen Recycle Compressor
•The Problem
•Performance Trends
•Compressor Crash
•Vibration analysis
•Internal Inspection of Compressor
•Investigation
•Resolution
•Lessons Learnt
Description
Case StudySubject
TurbomachinesCollections
Citation
Zahid, Muhammad; Venkatesh, Devrajan; Raju, N.K.; Holt, Christopher (2015). Compressor rotor failure due to fouling at Qatargas condensate refinery. Turbomachinery Laboratory, Texas A&M Engineering Experiment Station. Available electronically from https : / /hdl .handle .net /1969 .1 /172653.