dc.contributorAsia Turbomachinery & Pump Symposium (2nd : 2018)
dc.creatorAli, Haider
dc.creatorHaseeb Bukhari, Syed
dc.creatorAkram Awan, Asad
dc.creatorMansoor, Mojiz
dc.creatorBurrero, Nooruddin
dc.date.accessioned2018-10-12T15:25:09Z
dc.date.available2018-10-12T15:25:09Z
dc.date.issued2018
dc.identifier.urihttps://hdl.handle.net/1969.1/172481
dc.descriptionCase Studiesen
dc.description.abstractFailure of an industrial scale bevel gear assemble in 2.5 years of its commissioning. The gear box drives a pumps rated at 16240m3/h at 47.5 meter of head. The unit developed an abnormal noise with slightly higher impacting (vibration waveform) on the gearbox. However upon inspection, increased back-lash (still in recommended limit) was observed on the unit and the machine was kept in operation. During a startup in March 2014, high cyclic impacting was observed in vibration waveform which indicated gearbox wear/damage. Upon inspection leading edge teeth of the bevel gearbox was found broken. Further investigation revealed increased backlash and change in contact area of the gears. The case study covers the complete RCA of GB failure and the remedial action taken on similar units installed on site.en
dc.format.mediumElectronicen
dc.format.mimetypeapplication/pdf
dc.language.isoen
dc.publisherTurbomachinery Laboratory, Texas A&M Engineering Experiment Station
dc.relation.ispartofAsia Turbomachinery & Pump Symposium. 2018 Proceedings.en
dc.subject.lcshTurbomachinesen
dc.subject.lcshPumping machineryen
dc.titleCooling Water Pump Gearbox Diagnostics, Failure and Remedial Actionsen
dc.type.genreconference publicationen
dc.type.materialTexten
dc.format.digitalOriginborn digitalen


Files in this item

Thumbnail

This item appears in the following Collection(s)