dc.contributorAsia Turbomachinery & Pump Symposium (2nd : 2018)
dc.creatorChavda, Bhagyesh
dc.creatorAshraf, Saquib
dc.creatorKocur, John
dc.creatorBaer, Heinrich
dc.date.accessioned2018-10-12T15:24:58Z
dc.date.available2018-10-12T15:24:58Z
dc.date.issued2018
dc.identifier.urihttps://hdl.handle.net/1969.1/172474
dc.descriptionCase Studiesen
dc.description.abstractThree shaft Gear Box upgraded to meet Screw compressor model upgrade. Gear Box was installed, as a part of compressor upgrade project, with Bentley Nevada 3500 Shaft vibration protection facility and observed trip on commissioning. Detail analysis of shaft vibration plots clearly indicated sub-synchronous vibration component as source of machine trip which is attributed due to Fluid instability inside the bearing. The case study represents gear box shaft high vibration detail analysis and proposed Bearing Modification for resolution.en
dc.format.mediumElectronicen
dc.format.mimetypeapplication/pdf
dc.language.isoen
dc.publisherTurbomachinery Laboratory, Texas A&M Engineering Experiment Station
dc.relation.ispartofAsia Turbomachinery & Pump Symposium. 2018 Proceedings.en
dc.subject.lcshTurbomachinesen
dc.subject.lcshPumping machineryen
dc.titleGear Box Bull Gear High Vibration due to Fluid Instability and Analytical Evaluation of New Bearing Designen