Show simple item record

dc.contributorAsia Turbomachinery & Pump Symposium (2nd : 2018)
dc.creatorMoin, Danish
dc.date.accessioned2018-10-12T15:24:10Z
dc.date.available2018-10-12T15:24:10Z
dc.date.issued2018
dc.identifier.urihttps://hdl.handle.net/1969.1/172444
dc.descriptionCase Studiesen
dc.description.abstractUrea melt pumps had been a reliability concern since commissioning (1992). Majority of the concerns were related to the failure of mechanical seal. Unexpected failures of seal were encountered during plant startups or during pump changeover. It resulted in a major reliability concern as the continuity of operation of plant had been at stake. Also huge expenses were incurred as damaged seal caused other parts to fail. A typical overhaul costs around USD 10,000. This Case Study highlights the identification of Failure Modes and steps taken to resolve the issues pertaining to seal reliability on this service.en
dc.format.mediumElectronicen
dc.format.mimetypeapplication/pdf
dc.language.isoen
dc.publisherTurbomachinery Laboratory, Texas A&M Engineering Experiment Station
dc.relation.ispartofAsia Turbomachinery & Pump Symposium. 2018 Proceedings.en
dc.subject.lcshTurbomachinesen
dc.subject.lcshPumping machineryen
dc.titleMolten Urea Transfer Pump Seal Failuresen
dc.type.genreconference publicationen
dc.type.materialTexten
dc.format.digitalOriginborn digitalen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record