Show simple item record

dc.contributor.advisorYeh, Alvin T
dc.creatorBustamante Lopez, Sandra Catalina
dc.date.accessioned2018-02-05T16:49:41Z
dc.date.available2019-08-01T06:51:47Z
dc.date.created2017-08
dc.date.issued2017-06-02
dc.date.submittedAugust 2017
dc.identifier.urihttps://hdl.handle.net/1969.1/165738
dc.description.abstractFor diabetics, continuous glucose monitoring, and the resulting tighter control of glucose levels, ameliorates serious complications from hypoglycemia and hyperglycemia. Today, diabetics measure their blood glucose levels multiple times a day by finger pricks, or use implantable monitoring devices. Still, glucose and other analytes in the blood fluctuate throughout the day and the current monitoring methods are invasive, immunogenic, and/or present biodegradation problems. Using carrier erythrocytes loaded with a fluorescent sensor, we seek to develop a biodegradable, efficient, and potentially cost effective method for long-term monitoring of blood analytes. We aim to reintroduce sensor-loaded erythrocytes to the bloodstream and conserve the erythrocytes lifetime of 120 days in the circulatory system. Here, the efficiency of two loading procedures is compared. Hypotonic dilution employs hypotonic buffer to create transient pores in the erythrocyte membrane, allowing dye entrance and a hypertonic buffer to restore tonicity. Electroporation relies on controlled electrical pulses that results in reversible pores formation to allow cargo entrance. As part of the cellular characterization of loaded erythrocytes, size and hemoglobin content was evaluated. Cell recovery and fluorescence per cell measurements also render optimal loading conditions. Furthermore, AFM and confocal microscopy protocols were implemented to evaluate morphological changes induced by hypotonic dilution. The development of a suitable protocol to engineer carrier erythrocytes has profound and lasting implications in the erythrocytes’ lifespan and sensing capabilities.en
dc.format.mimetypeapplication/pdf
dc.language.isoen
dc.subjectErythrocytesen
dc.subjectErythrosensorsen
dc.subjectcell-based sensoren
dc.subjectAFMen
dc.subjectBiosensorsen
dc.subjectConfocalen
dc.titleErythrosensors Cellular Characterizationen
dc.typeThesisen
thesis.degree.departmentBiomedical Engineeringen
thesis.degree.disciplineBiomedical Engineeringen
thesis.degree.grantorTexas A & M Universityen
thesis.degree.nameDoctor of Philosophyen
thesis.degree.levelDoctoralen
dc.contributor.committeeMemberMeissner, Kenith E
dc.contributor.committeeMemberMaitland, Kristen C
dc.contributor.committeeMemberHan, Arum
dc.type.materialtexten
dc.date.updated2018-02-05T16:49:41Z
local.embargo.terms2019-08-01
local.etdauthor.orcid0000-0002-8854-7558


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record