A Comprehensive Review of the Tests Completed on the Flow Loop at the Energy Systems Laboratory (Draft)
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1992)
In 1988 the Governor's Energy Office (GEO) of Texas received approval from the U.S.
Department of Energy to establish a $98.6 million state-wide retrofit demonstration
program, the LoanSTAR (Loan to Save Taxes and ...
Calculating Energy and Demand Retrofit Savings for Stroman High School: Interim Report
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1992)
As part of the LoanSTAR program, Stroman High School in Victoria Texas underwent
two retrofits: a) an absorption chiller was changed to an electric vapor compression
chiller, and b) an EMCS system was installed after ...
Calculating Energy and Demand Retrofit Savings for Victoria High School: Interim Report
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1992)
As part of the LoanSTAR program, Victoria High School in Victoria, Texas underwent
two retrofits: a) an absorption chiller was changed to an electric vapor compression
chiller, and b) an EMCS system was installed after ...
Calibrating DOE-2 to Weather and Non-Weather-Dependent Loads for a Commercial Building: Data Processing Routines to Calibrate a DOE-2 Model, Volume II
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1992)
DOE-2 yields hourly data on specific variables provided the user specifies the
HOURLY-REPORT instruction. Analyzing the simulation results with hourly data gives a more
detailed picture of how well the model is predicting ...
Monitoring the Performance of a Residential Central Air Conditioner under Degraded Conditions on a Test Bench
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1992)
This report presents the measured degradation in performance of a residential air conditioning
system operating under degraded conditions. Experiments were conducted using a R-22 threeton
split-type cooling system with ...
LoanSTAR Monitoring and Analysis Program Building Energy Monitoring Workbook Submitted to the Texas Governor’s Energy Office by the Improved Energy Audit Process Task (Aug. 1992)
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1992)
This building energy monitoring workbook has been prepared for the Texas Governor's
Energy Office by the Improved Energy Audit Task of the LoanSTAR Monitoring and
Analysis Program. This workbook is intended to be a ...
A Field Study on Residential Air Conditioning Peak Loads During Summer in College Station, Texas
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1992)
Severe capacity problems are experienced by electric utilities during hot summer afternoons.
Several studies have found that, in large part, electric peak loads can be attributed to residential airconditioning
use. This ...
Prairie View A&M University Whole Campus Energy Report Update
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1992)
Prairie View A&M University started a large scale energy management program in 1987 and 1988. This
updated report presents an analysis of whole-campus energy consumption at the Prairie View A&M Campus
where whole-campus ...