(2018-02-06)
-
(Energy Systems Laboratory, 2006-06)
-
(2008-07-18)This study examines the difference of the window simulation test between the Shading Coefficient (SC) and the Window Library (WL) Methods on DOE 2.1E of the 2000 IECC (International Energy Conservation Code) for single-family ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1994)Two stainless steel toilets using the 1.6 gallon per flush valve were tested and are documented in this report. One toilet is a version of the existing TDC water closet design (designated TDC5) and represents a retrofit ...
-
(2006-11-09)In 1993, the U.S. Environmental Protection Agency initiated a project to design, build and demonstrate a high efficiency commercial rooftop air conditioning unit. The unit was designed by Hibberd Consulting of Westminster, ...
-
Texas Emissions and Energy Calculator (eCALC): Documentation of Analysis Methods, Report to the TCEQ (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2004)This report provides documentation about the Energy Systems Laboratory’s Emissions and Energy Calculator (eCALC), including information about the web structure, new building models, and community projects. In each of the ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1989)Major objectives of the LoanSTAR Monitoring and Analysis Program (MAP) are to: verify energy and dollar savings of energy conservation retrofits in state, school and local government buildings; reduce energy costs by ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1990)Eleven audit reports have been accepted by the review staff at Texas A&M University. These eleven reports cover 3.8 million square feet of building space and two street-lighting projects. One engineer has been employed ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1993)
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1991)The LoanSTAR program has now completed its second prototype year. This report is Volume I of a two volume set that documents the progress since the January 1991 MARC meeting. This first voume contains photocopies of the ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1991)The LoanSTAR program has now completed its second prototype year. This report is Volume II of a two volume set that documents the progress since the January 1991 MARC meeting. This second volume contains papers and ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1994)The Texas LoanSTAR (Loans to Save Taxes and Resources) Program is a $98.6 million revolving loan fund to finance energy conservation retrofits in Texas government buildings. The loans are repaid through energy cost savings ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1991)
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2003)This is the report and manual for the Texas LoanSTAR Program Savings Calculation Workbook. The purpose of this report is to document the Texas LoanSTAR Program Savings Calculation Workbook to be used by the State Energy ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2002)Four areas in Texas have been designated by the EPA as non-attainment areas because ozone levels exceed the NAAQS maximum allowable limits, Beaumont-Port Arthur, El Paso, Dallas-Ft. Worth, and Houston-Galveston-Brazoria. ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2002)This is the first annual report by the Energy Systems Laboratory, which covers the Laboratory's efforts to support Senate Bill 5. In this report the accomplishments and progress to date are presented, along with recommendations, ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2002)This report outlines the Energy Systems Laboratory's responsibilities in Senate Bill 5, accomplishments to date, recommendations to the TERP Advisory Group, and problems encountered to date and what is needed to fulfill ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1994)Recently third-party financing has become a popular mechanism for funding energy conservation retrofits in commercial/institutional buildings. Although many successful projects have been heralded by the press quite a few ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2012)
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1994)The present study presents data for flow of two refrigerant mixtures through short tube orifices. The two mixtures were R3211251134a (23%/25%/52% on a mass percentage basis) and R321125 (50%/50%). The following presents ...