Control Humidity With Single-Duct, Single-Zone, Constant Air Volume System
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2000)
The lecture hall of the Richardson Petroleum
Building at Texas A&M University is a large lecture
hall, with a total floor area of approximately 2500 ft^2.
The lecture hall was served by a constant air volume
(CAV) air ...
Lessons Learned From the Continuous Commissioning of a Multi-Functional Commercial Building
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2000)
A multi-functional institutional building often
has ventilation and comfort requirements that vary
widely from zone to zone. When we commissioned
the Reed McDonald building on the main campus of
Texas A&M University (TAMU), ...
Procedures for Filling Short Gaps in Energy Use and Weather Data
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2000)
Filling short gaps (a few hours) in hourly
energy use and weather data can be useful for (i)
retrofit savings analysis and calculation, and for (ii)
diagnostic purposes. The paper evaluates four
methods for rehabilitating ...
The Brazos Valley Energy Conservation Coalition, Part of the Rebuild America Program in Texas: Program Update
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2000)
The Rebuild America program is network of
community-based partnerships that rebuilds
communities by promoting the efficient use of
energy. Rebuild America is coordinated at the
national level by sponsorship through the ...
Improved Air Volume Control Logic for VAV Systems
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2000)
In a VAV (variable air volume) system, the set
point of the static pressure (usually measured at 213
downstream of the main supply air duct) is
maintained by modulating the fan speed or inlet
guide vane position. The set ...
An Exploratory Initiative for Improving Low-Cost Housing in Texas
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2000)
In 1996 the Real Estate Center at Texas A&M University released a report indicating that the population of Texas would double in the next 30 years and that a majority of the 18 million new Texans would be have low to ...
Investigation of PVC Pipe Failure at Terrell State Hospital – Final Report
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2000)
At the request of Terrell State Hospital and MHMR, the Energy Systems Laboratory at Texas A&M University investigated the failure of the PVC pipes serving the chilled water loop at Terrell State Hospital. There were two ...
Compilation of Diversity Factors and Schedules for Energy and Cooling Load Calculations, ASHRAE Research Project 1093, Phase III Draft Report, Compilation of Diversity Factors and Load Shapes
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2000)
This is a draft of the Final Report in the ASHRAE RP-1093 project that, first summarizes the work completed during the scheduled Phase I and Phase II (presented to the PMSC in Seattle - June 1999, and Dallas February 2000), ...
Integrated Commissioning for a Large Medical Facility
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2000)
The energy costs of heating, ventilating and
air conditioning usually represents a large
portion of the utility bills for a medical facility.
One large, modem medical center located in the
hot and humid region of southern ...
Data Visualization for Quality-Check Purposes of Monitored Electricity Consumption in All Office Buildings in the ESL Database
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2000)
This report comprises an effort to visualize the monitored electricity consumption in all office buildings (not including the office buildings comprising other functions as classrooms and laboratories, for instance) in the ...