15% Above-Code Energy Efficiency Measures for Residential Buildings in Texas
(Energy Systems Laboratory (http://esl.tamu.edu), 2007-08)
In the pages that follow, 15% above-code measures for new residential buildings are presented
for the 41 non-attainment and affected counties in Texas, separated by climate area. Each page
contains a description of the ...
Recommendations for 15% Above-Code Energy Efficiency Measures for Single Family Residences
(Energy Systems Laboratory (http://esl.tamu.edu), 2007-12)
Energy Efficiency/Renewable Energy Impact in the Texas Emissions Reduction Plan (TERP)
(Energy Systems Laboratory (http://esl.tamu.edu), 2007-12)
Reduced Order Modeling of Heat Exchangers Using High Order Finite Control Volume Models
(2007-12)
A distributed parameter approach for dynamic modeling of heat exchangers and using it to obtain low order models have been presented in this report. The finite control volume (FCV) approach accurately captures the distributed ...
Energy Efficiency/Renewable Energy Impact in the Texas Emissions Reduction Plan (TERP), Volume II - Technical Report, Annual Report to the Texas Commission on Environmental Quality, January 2006 - June 2007
(Energy Systems Laboratory, 2007-08)
The Energy Systems Laboratory, at the Texas Engineering Experiment Station of the Texas A&M University System, in fulfillment of its responsibilities under Texas Health and Safety Code Ann. 388.003 (e), Vernon Supp. 2002, ...
Commissioning of a Coupled Earth Tube and Natural Ventilation System at the Design Phase
(Texas A&M University (http://www.tamu.edu)Energy Systems Laboratory (http://esl.tamu.edu), 2007)
Natural ventilation airflow rate is generally calculated using indoor and outdoor temperature difference without consideration of thermal interaction between the ventilated air and the room in simple analytical method based ...
Recommendations for 15% Above-Code Energy Efficiency Measures for Single-Family Residences
(Texas A&M University (http://www.tamu.edu)Energy Systems Laboratory (http://esl.tamu.edu), 2007-12)
This paper presents an overview of the recommendations for achieving 15% above-code energy performance for single-family residences. The analysis was performed using a simulation model of an International Energy Conservation ...
Air Handling Unit Supply Air Temperature Optimization During Economizer Cycles
(Texas A&M University (http://www.tamu.edu)Energy Systems Laboratory (http://esl.tamu.edu), 2007)
Most air handling units (AHUs) in commercial buildings have an air economizer cycle for free cooling under certain outside air conditions. During the economizer cycle, the outside air and return air dampers are modulated ...
Continuous Commissioning of the Reynolds Army Community Hospital, Fort Sill, Oklahoma
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2007)
Continuous Commissioning® (CC®) of the Reynolds Army Community Hospital facility was a two phase project. The first phase consisted of a point-to-point verification of a newly upgraded Energy Management Control System ...
Impacts of Static Pressure Reset on VAV System Air Leakage, Fan Power and Thermal Energy - Part I: Theoretical Model and Simulation
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2007)
As for a variable air volume (VAV) system, the air duct static pressure is a typical control variable maintained by modulating supply fan speed. The static pressure equals to the summation of the duct pressure loss downstream ...