Disaggregating Cooling Energy Use of Commercial Buildings Into Sensible and Latent Fractions From Whole-Building Monitored Data: Methodology and Advantages
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1992-05)
In hot and humid climates, where summers are both warm and humid, the latent cooling can be a significant portion of the total cooling load (as much as 40%). Typically the monitored data only includes whole-building heating ...
Analysis of Texas LoanSTAR Data
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1990)
The analysis effort during the first year of the Texas LoanSTAR
Monitoring and Analysis Program has emphasized selection and
development of baseline analysis techniques to cover the range
of buildings expected in the ...
Improved Analysis Methods for Retrofit Savings and Energy Accounting (ERAP #227)
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1990)
This report summarizes progress through November, 1990 for ERAP project No. 227, "Improved Analysis Methods for Retrofit Savings and Energy Accounting." The major objectives of this project are to: (1) determine the energy ...
Calculating Energy and Demand Retrofit Savings for Stroman High School: Interim Report
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1992)
As part of the LoanSTAR program, Stroman High School in Victoria Texas underwent
two retrofits: a) an absorption chiller was changed to an electric vapor compression
chiller, and b) an EMCS system was installed after ...
Calculating Energy and Demand Retrofit Savings for Victoria High School: Interim Report
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1992)
As part of the LoanSTAR program, Victoria High School in Victoria, Texas underwent
two retrofits: a) an absorption chiller was changed to an electric vapor compression
chiller, and b) an EMCS system was installed after ...
Potential Operation and Maintenance (O&M) Savings at the State Capitol Complex
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
This report presents the results of a study of the potential cost savings by improving
operations and maintenance (O&M) practices at eight buildings of the State Capitol
Complex, monitored by the LoanSTAR program. This ...
Simulation of the Post-Retrofit Thermal Energy Use for the Perry-Castaneda Library Building with the Use of Simplified System Models
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1991)
Several state owned buildings with dual-duct constant volume (DDCV) systems are
being retrofitted with energy efficient variable air volume (VAV) systems as part of Texas
LoanSTAR Program. One method of determining the ...
An Overview of Measured Energy Retrofit Savings Methodologies Developed in the Texas LoanSTAR Program
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1994)
Development of methodologies to determine energy retrofit savings in commercial buildings (institutional buildings, schools, hospitals, offices, county and state buildings,...) has been the object of active research during ...
Simulation of the Post-Retrofit Thermal Energy Use for the University Teaching Center (UTC) Building with the Use of Simplified System Models
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1991)
Several state owned buildings with dual-duct constant volume (DDCV) systems have
been retrofitted with energy efficient variable air volume systems (VAV) as part of the
Texas LoanSTAR Program. One method of determining ...
Bias in Predicting Annual Energy Use in Commercial Buildings with Regression Models Developed from Short Data Sets
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1994)
An empirical or regression modeling approach is simple to develop and easy to use compared to use of detailed hourly simulations. Therefore, regression analysis has become a widely used tool in the determination of annual ...