Show simple item record

dc.contributor.otherInternational Pump Users Symposium (15th : 1998)
dc.creatorPembroke, John P.
dc.creatorSabini, Eugene P.
dc.creatorLittlefield, David E.
dc.date.accessioned2017-10-05T16:53:17Z
dc.date.available2017-10-05T16:53:17Z
dc.date.issued1998
dc.identifier.urihttps://hdl.handle.net/1969.1/164127
dc.descriptionLectureen
dc.descriptionpg. 11en
dc.description.abstractIn 1991, four large double suction cooling pumps were installed at a chemical plant in Texas. Although these pumps met performance specifications on the test stand, they proved to be noisy when installed. Sound power levels greater than 93 dbA were observed. Pumping applications involving cooling water have been especially difficult to solve over the tears, due to the presence of dissolved air inherent in a cooling tower sump. Water that contains large amounts of dissolved air changes the apparent required net positive suction head (NPSH). In such applications, traditional correction techniques failed because the entire system was not analyzed, and the source of the noise generation could not be pinpointed. This paper deals with the steps involved with obtaining a solution to this problem. A computational fluid dynamics (CFD) analysis was performed on the pump and impeller. Initial investigation revealed that the impeller was not the source of the problem. The casing inlet was then analyzed. The model indicated the presence of separation in the suction nozzle, causing a flow distortion at the impeller eye. A unique guide ring was developed to minimize the flow separation. The CFD analysis was revised to reflect the new geometry, and a significant improvement in the flow was predicted. A prototype guide ring was manufactured and installed in one of the four pumps. Pressure profiles were obtained by experiment to validate the analyses. The results are discussed.en
dc.format.mediumElectronicen
dc.format.mimetypeapplication/pdf
dc.language.isoen
dc.publisherTexas A&M University. Turbomachinery Laboratories
dc.relation.ispartofProceedings of the 15th International Pump Users Symposiumen
dc.subject.lcshPumping machineryen
dc.titleCFD Analysis Of A Double Suction Cooling Water Pumpen
dc.type.genrePresentationen
dc.type.materialTexten
dc.identifier.doihttps://doi.org/10.21423/R1G97C


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record