Intermittent Spikes On Vibration And Motor Current Caused By Water Carryover On The Third Stage Of A Centrifugal Air Compressor.
dc.contributor.other | Turbomachinery Symposium (38th : 2009) | |
dc.creator | Vázquez, José A. | |
dc.creator | Addison, Bradley | |
dc.creator | Eizember, Robert J. | |
dc.creator | Moore, James C. | |
dc.creator | Locke, Stephen R. | |
dc.date.accessioned | 2017-10-04T21:23:10Z | |
dc.date.available | 2017-10-04T21:23:10Z | |
dc.date.issued | 2009 | |
dc.identifier.uri | https://hdl.handle.net/1969.1/163096 | |
dc.description | Case Study | en |
dc.format.medium | Electronic | en |
dc.format.mimetype | application/pdf | |
dc.language.iso | en | |
dc.publisher | Texas A&M University. Turbomachinery Laboratories | |
dc.relation.ispartof | Proceedings of the 38th Turbomachinery Symposium | en |
dc.subject.lcsh | Turbomachines | en |
dc.title | Intermittent Spikes On Vibration And Motor Current Caused By Water Carryover On The Third Stage Of A Centrifugal Air Compressor. | en |
dc.type.genre | Presentation | en |
dc.type.material | Text | en |
dc.identifier.doi | https://doi.org/10.21423/R1JD24 |