Show simple item record

dc.contributor.otherInternational Pump Users Symposium (31st : 2015)
dc.creatorVisser, Frank
dc.creatorBastiaansen, Tim
dc.creatorVan-den-Berg, Nico
dc.creatorAl-Shuhail, Yousuf S.
dc.creatorAl-Ali, Saad A.
dc.creatorAl-Qahtani, Abdulaziz N.
dc.date.accessioned2017-09-09T21:58:54Z
dc.date.available2017-09-09T21:58:54Z
dc.date.issued2015
dc.identifier.urihttps://hdl.handle.net/1969.1/162222
dc.descriptionCase Studyen
dc.format.mediumElectronicen
dc.format.mimetypeapplication/pdf
dc.language.isoen
dc.publisherTurbomachinery Laboratories, Texas A&M Engineering Experiment Station
dc.relation.ispartofProceedings of the 31st International Pump Users Symposiumen
dc.subject.lcshPumping machineryen
dc.titleEliminating Cavitation Damage In High-Energy Water Injection Pumps By Suction Impeller Redesignen
dc.type.genrePresentationen
dc.type.materialTexten
dc.format.digitalOriginborn digitalen
dc.identifier.doihttps://doi.org/10.21423/R17P70