dc.description.abstractThe slotted plate flow meter has been widely tested as an obstruction flow meter during the past several years. It has been tested for both single-phase flows as well as for two-phase flows. Previous studies have revealed that the slotted plate flow meter is always better in performance and accuracy than the standard orifice plate flow meter. This study is primarily based on how a slotted plate responds to horizontal two-phase flow with air and water being used as the working fluids. The plates under consideration are those with beta ratios of 0.43 and 0.467. Experiments have been performed with six different configurations of the slotted plate test sections. The performances of the slotted plate flow meters will be compared to that of a standard orifice plate flow meter and then with a venturi. The effects of varying the upstream quality of the two-phase flow on the differential pressure and the coefficient of discharge of the slotted plates, the standard orifice plate and the venturi will be evaluated. Response characteristics at low differential pressures will be investigated. Tests for repeatability will be performed by studying the effects of the gas Reynolds number and the upstream quality on the differential pressure. The differential pressures across the slotted plates, the standard orifice plate and the venturi will be compared. Reproducibility will be evaluated by comparing the data obtained from all six different configurations. One of the main objectives of this study is to arrive at the best suitable procedure for accurately measuring the flow rate of two-phase flow using the slotted plate flow meter.en
dc.format.extent5907548 bytesen
dc.format.mediumelectronicen
dc.format.mimetypeapplication/pdf
dc.language.isoen_US
dc.publisherTexas A&M University
dc.subjecttwo phase flowen
dc.subjectslotted plateen
dc.subjectflowmeteren
dc.subjectexperimenten
dc.titleResponse of a slotted plate flow meter to horizontal two phase flowen
dc.typeBooken
dc.typeThesisen
thesis.degree.departmentMechanical Engineeringen
thesis.degree.disciplineMechanical Engineeringen
thesis.degree.grantorTexas A&M Universityen
thesis.degree.nameMaster of Scienceen
thesis.degree.levelMastersen
dc.contributor.committeeMemberRhode, David
dc.contributor.committeeMemberHall, Kenneth
dc.type.genreElectronic Thesisen
dc.type.materialtexten
dc.format.digitalOriginborn digitalen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record