Search
Now showing items 1-1 of 1
High Vibration Analysis of Eddy Current Drum Coupled Motor to a Vertical Centrifugal Pump : Solution Based on EMA, ODS and FEA
(Turbomachinery Laboratories, Texas A&M Engineering Experiment Station, 2016)
The 35-year old pump station moves up to 43 MGD of raw wastewater to the city’s treatment facility via two 1,500-hp high-capacity pumps for wet weather flows. After the motors were refurbished in 2011, excessive motor ...