Search
Now showing items 1-6 of 6
Factors Affecting Oil Ring And Slinger Lubricant Delivery & Stability
(Turbomachinery Laboratories, Texas A&M Engineering Experiment Station, 2014)
The choice of which lubrication strategy to apply for pump bearings has implications for both the short term characteristics exhibited by the bearings and their long term reliability. When lubricating rolling element ...
The Development, Testing, And Successful Application Of Arrangement 2 Seals For Co2 Pipelines
(Turbomachinery Laboratories, Texas A&M Engineering Experiment Station, 2014)
The use of CO2 for Enhanced Oil Recovery (EOR) has been around since the early 70’s and was developed to enable oil extraction from declining fields. The process involves injecting CO2 from either natural or man-made sources ...
A Lateral Rotordynamics Primer On Electric Submersible Pumps (ESPS) For Deep Subsea Applications
(Turbomachinery Laboratories, Texas A&M Engineering Experiment Station, 2014)
Preview Of API 610 12th Edition
(Turbomachinery Laboratories, Texas A&M Engineering Experiment Station, 2014)
API 610 Eleventh Edition, Centrifugal Pumps for Petroleum, Petrochemical and Natural Gas Industries, is being updated to the Twelfth Edition. The Eleventh Edition was identical to the ISO 13709 Second Edition; however, API ...
Repetitive Shaft Crack Failure Analysis On A Multistage Centrifugal Pump In Reactor Charge Service In A Nuclear Power Plant - Based On ODS And FEA
(Turbomachinery Laboratories, Texas A&M Engineering Experiment Station, 2014)
Two multistage barrel type pumps were installed in a nuclear power plant in reactor charge application. The pumps are driven by a 600 HP (447 kW) four-pole induction motor through double helical gear increasers. The overall ...
What Constitutes 'High Energy' In Centrifugal Pumps?
(Turbomachinery Laboratories, Texas A&M Engineering Experiment Station, 2014)
Every engineer has his own idea of what makes a centrifugal pump a high energy pump, but getting 2 or more engineers to agree on a definition of "High Energy" is difficult. Is a pump high energy because it runs at > 6000 ...