Influence of Infrared Radiation on Attic Heat Transfer
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1985)
An experimental study concerned with different modes
of heal transfer in fibrous and cellulose insulating material
is presented. A series of experiments were conducted using
an attic simulator to determine the effects of ...
Simulation of Dehumidification Characteristics of High Efficiency Residential Central Air-Conditioners in Hot and Humid Climates
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1988)
This study assesses the dehumidifying performance
of the high efficiency residential central air conditioners
(CAC) in hot/humid climates typified
by that of Houston and Galveston. The performance
study is based on such ...
An Evaluation of Steady-State Dehumidification Characteristics of Residential Central Air Conditioners, Final Report
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1987)
This report is the first of two reports on the project
"Determination of the Transient Response Characteristics of High
Efficiency Commercial Air Conditioners" funded by Houston Lighting and
Power Company. The purpose ...
An Energy and Peak Loads Analysis of the Texas Department of Health Building, Final Report, Prepared for the Energy Efficiency Division, Texas Public Utility Commission
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1986)
An Energy and Peak Loads Analysis of the TYC/TRC Building – Final Report
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1987)
The energy use of the Texas Youth Commission/Texas Rehabilitation
Commission (TYC/TRC) Building at Austin, Texas, was analyzed using
the DOE 2.IB building energy simulation program. An analysis was made
for the building ...
A Computer Analysis of Energy Use and Energy Conservation Options for a Twelve Story Office Building in Austin, Texas
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1986)
The energy use of the Travis Building
at Austin, Texas was analyzed using the DOE
2.1B building energy simulation program.
An analysis was made for the building as
specified in the building plans and as
operated by the ...
Determination of the Transient Dehumidification Characteristics of High Efficiency Central Air Conditioners
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1987)
A series of tests were performed to assesses the dehumidifying performance
of residential central air conditioners (CACs). The performance studies were
based on factors such as: (i) dynamic performance (ii) the ASHRAE ...
Energy Use and Design Options for Texas State Buildings
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1988)
In 1984, the Office of Governor in the State of Texas, working through
the Energy Efficiency Division of the Public Utility Commission, instituted
a program to reduce the energy costs in state owned buildings. One
facet ...
An Evaluation of the Placement of the Placement of Radiant Barriers on their Effectiveness in Reducing Heat Transfer in Attics
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1986)
Experimental tests were conducted to
measure the influence of radiant barriers
and the effect of the radiant barrier
location on attic heat transfer. All the
tests were conducted in an attic simulator
at a steady state. ...