Determining The Cause Of Bearing Failures In Circulating Water Pump Motors
(Texas A&M University. Turbomachinery Laboratories, 2004)
Eight vertical circulating water pumps are used to circulate condenser water at the generation station in a nuclear power plant. The pump installation is pictured in Figure 1. The motor pump system is arranged vertically ...