Determining Long-Term Performance of Cool Storage Systems from Short-Term Tests, Progress Report, 6-99, Revised 12-99
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1999)
This is the Spring 1999 progress report on ASHRAE Research Project RP 1004: Determining Long-Term Performance of Cool Storage Systems from Short-Term Tests. This report presents an update concerning the work that has been ...
Report of Energy Efficiency Study and Metering/Utilities Profile for Electric Deregulation at Tarleton State University (TSU), Stephenville, Texas
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1999)
The director of Energy Management & Controls and staff at Tarleton State University (TSU) do a very good job of maintaining TSU and keeping expenses down. They have metering installed in many buildings and track the campus ...
Report of Energy Efficiency Study and Metering/Utilities Profile for Electricity Deregulation at Texas A&M International University (TAMIU) Laredo, Texas
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1999)
The physical plant director and staff at Texas A&M International University at Laredo do a very good job of maintaining TAMIU facilities. During our visit, however, we were able to identify several opportunities for improving ...
Report of Energy Efficiency Study and Metering/Utilities Profile for Electricity Deregulation at Texas A&M University -- Galveston (TAMU-G) Galveston, Texas
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1999)
The physical plant director and staff at Texas A&M University at Galveston (TAMU-G) do a very good job of maintaining TAMU-G facilities and keeping expenses down. During our visit, however, we were able to identify several ...
Report of Energy Efficiency Study and Metering/Utilities Profile for Electricity Deregulation at Texas A&M University – Commerce (TAMU–C) Commerce, Texas
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1999)
The energy costs for TAMU-Commerce are very high when compared to most of the other universities in the TAMUs. For example, the price of $1.6 per square foot per year for utilities is nearly twice that of the Kingsville ...
Report of Energy Efficiency Study and Metering/Utilities Profile for Electricity Deregulation at Texas A&M University – Texarkana (TAMU–T) Texarkana, Texas
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1999)
The physical plant director at Texas A&M University - Texarkana (TAMU-T) does a very good job of maintaining TAMU-T facilities and keeping expenses down. During our visit, however, we were able to identify several opportunities ...
Field Performance Testing Of Gas Turbine Driven Compressor Sets.
(Texas A&M University. Turbomachinery Laboratories, 1999)
Field testing of gas turbine compressor packages requires the accurate determination of efficiency, flow, head, power, and fuel flow in sometimes less than ideal working environments. Nonetheless, field test results have ...
Redesign Of Large Steam Turbines For Increased Reliability.
(Texas A&M University. Turbomachinery Laboratories, 1999)
Two similar large steam turbines in an ethylene plant are profiled. One drives the cracked gas compressor train and the other
drives the propylene refrigeration compressor. The two machines are similar and this paper ...
Retrofitting A Large Steam Turbine With A Mechanically Centered Squeeze Film Damper.
(Texas A&M University. Turbomachinery Laboratories, 1999)
Reviewed is the application of a squeeze film damper to a large
steam turbine that addresses high vibration passing through the
first critical speed. The turbine was the fifth near identical machine
purchased over the ...
Unexpected Rotordynamic Instability In A "Proven" FCC Wet Gas Compressor.
(Texas A&M University. Turbomachinery Laboratories, 1999)
The cause and effects of a large subsynchronous vibration (3.5
mils at 3490 cpm) in an FCC wet gas compressor are examined.
The compressor is driven at 7850 rpm by a 6000 hp electric motor,
through a speed-increasing ...